Standards for Ballast Water Management
There is a ballast water exchange standard and a ballast water performance standard. Ballast water exchange could be used to meet the performance standard:
Regulation D-1 Ballast Water Exchange Standard - Ships performing Ballast Water exchange shall do so with an efficiency of 95 per cent volumetric exchange of Ballast Water. For ships exchanging ballast water by the pumping-through method, pumping through three times the volume of each ballast water tank shall be considered to meet the standard described. Pumping through less than three times the volume may be accepted provided the ship can demonstrate that at least 95 percent volumetric exchange is met.
Regulation D-2 Ballast Water Performance Standard - Ships conducting ballast water management shall discharge less than 10 viable organisms per cubic metre greater than or equal to 50 micrometres in minimum dimension and less than 10 viable organisms per milliliter less than 50 micrometres in minimum dimension and greater than or equal to 10 micrometres in minimum dimension; and discharge of the indicator microbes shall not exceed the specified concentrations.
The indicator microbes, as a human health standard, include, but are not be limited to:
a. Toxicogenic Vibrio cholerae (O1 and O139) with less than 1 colony forming unit (cfu) per 100 milliliters or less than 1 cfu per 1 gram (wet weight) zooplankton samples ;
b. Escherichia coli less than 250 cfu per 100 milliliters;
c. Intestinal Enterococci less than 100 cfu per 100 milliliters.
Ballast Water Management systems must be approved by the Administration in accordance with IMO Guidelines (Regulation D-3 Approval requirements for Ballast Water Management systems). These include systems which make use of chemicals or biocides; make use of organisms or biological mechanisms; or which alter the chemical or physical characteristics of the Ballast Water.